Metal Roof - RW3 Semi Rigid Slab

Installation Guide:

RW3 SEMI RIGID SLAB

Pitched Metal Roofs – Standing Seam systems
  
For built up metal roofing system applications (e.g. standing seam), Rockwool Acoustic Membrane should be applied between the metal outer sheet and insulation.

For enhanced performance, the membrane should also be positioned between the insulation layers as shown in construction below.
 
. Aluminium outer sheet

.
Rockwool Acoustic Membrane 5 (5kg/m2) – 1 layer

. Rockwool Cladding Roll

.
Rockwool Acoustic Membrane 5 (5kg/m2) – 2 layers

.
Rockwool RW3 Slab

.
Vapour Control Layer

.
Steel liner tray
 
In the absence of test data, Rockwool Limited have assessed that similar constructions with combinations of Rockwool Acoustic Membrane and Rockwool insulation materials are likely to achieve Weighted Sound Reduction Index values of up to 50 dB.
 
For installation of the Standing Seam system please contact the manufacturer.
 

Metal Roof with RW3 Semi Rigid Slab construction

A typical roof construction          

PrintPDF